Opens in a new tab

Daikin RXYMQ6AYFK

6.0 HP class · 16.0 kW nominal T1
VRV APT · Heat pump · R-410A

Daikin RXYMQ6AYFK is a 6 HP-class VRV APT heat pump outdoor unit for apartments and small premises, with a three-phase power supply. Nominal T1 cooling is 16.0 kW (54,500 Btu/h); H1 heating is 18.0 kW.

  • Compact single-fan, side-discharge design: 870 × 1,100 × 460 mm (H × W × D).
  • Nominal T3 cooling at 46°C: 14.5 kW.
  • R-410A refrigerant and inverter swing compressor.
  • Indoor units, controls and installation accessories selected separately.

AED  13,200.00

Technical Downloads

Daikin RXYMQ AVMK and AYFK VRV APT catalogue cover
RXYMQ Series
VRV APT catalogue
PDF · 46 pages · 17.8 MB
Daikin RXYMQ AVMK and AYFK engineering data book cover
RXYMQ Series
Engineering data book
PDF · 124 pages · 33.0 MB

Daikin RXYMQ6AYFK VRV APT outdoor unit

The 6 HP-class RXYMQ6AYFK provides cooling and heating through a designed network of Daikin VRV indoor units. Its 870 mm-high, side-discharge casing is intended for apartments and small premises where outdoor-unit space is limited. This model uses three-phase power; confirm the available electrical supply when comparing the AVMK and AYFK versions. HP denotes the VRV capacity class, not electrical input.

Cooling capacity and efficiency

Model / capacity class RXYMQ6AYFK / 6 HP
Nominal T1 cooling at 35°C 16.0 kW / 54,500 Btu/h
Nominal T3 cooling at 46°C 14.5 kW / 49,500 Btu/h
T1 power input, including indoor units 4.10 kW
T3 power input, including indoor units 4.90 kW
T3 outdoor-unit power input 4.74 kW
EER, T1 / T3 3.90 / 2.96 W/W
Cooling Seasonal Performance Factor, T3 5.35 W/W

T1 ratings use indoor air at 27°C dry bulb / 19°C wet bulb and outdoor air at 35°C dry bulb. T3 uses indoor air at 29°C dry bulb / 19°C wet bulb and outdoor air at 46°C dry bulb. The catalogue specifies ISO 15042:2011 for cooling ratings and ISO 16358-1:2013/AMD 1:2019 for hot-climate seasonal performance.

Heating and operating limits

Nominal H1 heating 18.0 kW / 61,500 Btu/h
Heating COP 4.25 W/W
Heating input, including indoor units 4.24 kW
Catalogue cooling operation range 0 to 54°C
Catalogue heating operation range −20 to 15.5°C

H1 heating ratings use indoor air at 20°C dry bulb and outdoor air at 7°C dry bulb / 6°C wet bulb. Operating limits do not imply nominal capacity at every temperature; select equipment for the intended design conditions.

Electrical supply, dimensions and refrigerant

Power supply 380–415 V / three-phase with neutral / 50 Hz; 400 V / 60 Hz
Dimensions H × W × D 870 × 1,100 × 460 mm
Compressor One hermetically sealed swing compressor
Cooling sound pressure 58 dB(A)
Refrigerant / listed unit charge R-410A / 5.4 kg
Liquid connection 9.5 mm OD, flare
Gas connection 19.1 mm OD, brazed

The listed refrigerant charge is the catalogue unit charge. Final charge, wiring, protective devices and pipe sizing depend on the complete installation. Allow the specified service clearances and airflow around the outdoor unit.

Compact installation and high-ambient design

The VRV APT range uses a refrigerant-cooled inverter PCB, additional PCB coating and a blue-coated heat exchanger. External static pressure up to 40 Pa allows installation designers to assess louvres or ducted discharge arrangements. Balcony, wall-mounted and stacked arrangements require suitable support and manufacturer installation clearances; the Daikin duplex mounting bracket is an option rather than an included accessory.

Indoor units and controls

The catalogue presents FXAQ-ARVM wall units, FXFSQ-ARV1 round-flow cassettes and concealed ducted indoor options. Match the exact indoor models, capacity indices, controls and piping as a complete VRV system. A permitted connection ratio does not guarantee simultaneous full output from every connected indoor unit.

Choose your RXYMQ VRV APT system

Compare the RXYMQ outdoor range by power supply, T1/T3 cooling and heating capacity. The original 46-page catalogue is available in Technical Downloads. Contact Coolwell on 800 26659355 for help selecting VRV equipment for a Dubai or UAE project.

Brand

Daikin

Series

RXYMQ-AYFK

T1 Cooling Capacity (Btu/h)

54,500

T1 Cooling Capacity (HP)

6.0

T1 Cooling Capacity (kW)

16.0

T1 Cooling Capacity (Ton)

4.54

Daikin RXYMQ-AVMK Mini VRV Apt ImageDaikin RXYMQ-AVMK Mini VRV Apt ImageDaikin RXYMQ-AVMK Mini VRV Apt ImageDaikin RXYMQ-AVMK Mini VRV Efficiency ImageDaikin RXYMQ-AVMK Mini VRV Features ImageDaikin RXYMQ-AVMK Mini VRV Application ImageDaikin RXYMQ-AVMK Mini VRV Space Saving ImageDaikin RXYMQ-AVMK Mini VRV Features ImageDaikin RXYMQ-AVMK Mini VRV Reliability ImageDaikin RXYMQ-AVMK Mini VRV Energy Efficiency ImageDaikin RXYMQ-AVMK Mini VRV Low Noise ImageDaikin RXYMQ-AVMK Mini VRV Easy Installation ImageDaikin RXYMQ-AVMK Mini VRV Design Flexibility ImageDaikin RXYMQ-AVMK Mini VRV Sleek ImageDaikin RXYMQ-AVMK Mini VRV Comfort ImageDaikin RXYMQ-AVMK Mini VRV Madoka ImageDaikin RXYMQ-AVMK Mini VRV Madoka ImageDaikin RXYMQ-AVMK Mini VRV Technical Specifications Image