Opens in a new tab

Daikin RXQ6ARYFK

6.0 HP class · 16.0 kW nominal T1
VRV X · Cooling only · R-410A

Daikin RXQ6ARYFK is a 6 HP-class VRV X cooling-only outdoor unit for multi-zone air conditioning. Nominal T1 cooling is 16.0 kW (54,600 Btu/h); T3 cooling at 46°C is 14.7 kW.

  • R-410A refrigerant with inverter scroll compression and Variable Refrigerant Temperature control.
  • Cooling operating range: 10–52°C outdoor dry bulb.
  • Dimensions H × W × D: 1,657 × 930 × 765 mm; net weight: 165 kg.
  • Three-phase power supply; compatible indoor units and controls selected separately.

AED  15,500.00

Technical Downloads

Daikin RXQ-ARYFK VRV X cooling-only catalogue cover
RXQ-ARYFK Series
VRV X catalogue
PDF · 34 pages · 16.7 MB
Daikin RXQ-ARYFK VRV X engineering data book cover
RXQ-ARYFK Series
Engineering data book
PDF · 160 pages · 42.3 MB
Daikin RXQ6ARYFK ESMA ECAS certificate preview
RXQ6ARYFK
ESMA certificate
PDF · 4 pages · 1480 KB
Valid until 4 March 2027

Daikin RXQ6ARYFK VRV X outdoor unit

The 6 HP-class RXQ6ARYFK supplies cooling to a designed network of Daikin VRV indoor units. It is a cooling-only outdoor unit for multi-room and multi-zone applications, with 16.0 kW nominal T1 capacity and 14.7 kW nominal T3 capacity. The HP value identifies the VRV capacity class; it is not the electrical input power.

Cooling performance and efficiency

Model / capacity class RXQ6ARYFK / 6 HP
Nominal T1 cooling 16.0 kW / 54,600 Btu/h
Nominal T3 cooling 14.7 kW / 50,000 Btu/h
T1 power input, including indoor units 4,500 W
T3 power input, including indoor units 5,100 W
T3 outdoor-unit power input 4,610 W
EER, T1 / T3 3.56 / 2.88 W/W
CSPF T3 for hot climates 4.76 W/W
Cooling operation range 10–52°C outdoor dry bulb

T1 ratings use indoor air at 27°C dry bulb / 19°C wet bulb and outdoor air at 35°C dry bulb. T3 ratings use indoor air at 29°C dry bulb / 19°C wet bulb and outdoor air at 46°C dry bulb. The catalogue bases these ratings on ISO 15042:2011 and the seasonal figure on ISO 16358-1:2013/AMD 1:2019.

The separate maximum T3 cooling figure of 14.8 kW applies at 19°C indoor wet bulb, 46°C outdoor dry bulb and a 130% indoor-unit connection ratio, for a limited number of hours. It is not the nominal T3 rating. The 52°C operating limit also does not imply nominal capacity at that temperature.

Variable refrigerant temperature and high-ambient design

Variable Refrigerant Temperature (VRT) control adjusts refrigerant temperature together with inverter compressor speed as the cooling load changes. The VRV X series combines scroll compression with a three-row heat exchanger and anti-corrosion fin treatment. A refrigerant-cooled inverter PCB supports operation in high ambient temperatures. The catalogue specifies outdoor external static pressure up to 78.4 Pa, subject to the installation design.

Dimensions, refrigerant and connections

Power supply 380–415 V / 3-phase / 50 Hz; 400 V / 3-phase / 60 Hz
Refrigerant / listed charge R-410A / 5.9 kg
Compressor type / quantity Hermetically sealed scroll / 1
Outdoor airflow 178 m³/min
Dimensions H × W × D 1,657 × 930 × 765 mm
Net machine weight 165 kg
Catalogue sound level 56 dB(A)
Liquid / gas piping connections 9.5 / 19.1 mm
Indoor-unit combination ratio 50–130%
Casing colour Ivory white

Allow for the 165 kg machine weight, service access and outdoor airflow when planning its location. The listed refrigerant charge is a catalogue unit value; final system charge and refrigerant pipe sizing depend on the connected indoor units and piping design.

Indoor units, controls and system selection

The catalogue’s indoor lineup includes FXAQ-ARVM wall units, FXFSQ-ARV1 round-flow cassettes and several concealed ducted ranges. Indoor-unit selection, connection ratio, controls and piping must be checked as a complete system. The stated 50–130% combination ratio is not a guarantee of simultaneous full output from every connected indoor unit.

Individual wired controls and central-management interfaces are described in the catalogue. Confirm the controller, interface and indoor-unit requirements for the project; they are not implied to be included with this outdoor-unit listing.

RXQ-ARYFK selection in Dubai and the UAE

Compare the RXQ-ARYFK range by nominal cooling capacity, high-ambient performance, electrical supply and installation space. Download the original 34-page Daikin VRV X catalogue in Technical Downloads for the full lineup and rating notes. Contact Coolwell on 800 26659355 for help selecting the outdoor unit and associated VRV equipment.

Brand

Daikin

Series

RXQ-ARYFK

T1 Cooling Capacity (Btu/h)

54,600

T1 Cooling Capacity (HP)

6.0

T1 Cooling Capacity (kW)

16.0

T1 Cooling Capacity (Ton)

4.55

Daikin RXQ-ARYFK VRV ImageDaikin RXQ-ARYFK VRV Features ImageDaikin RXQ-ARYFK VRV Cooling Only ImageDaikin RXQ-ARYFK VRV Features ImageDaikin RXQ-ARYFK VRV Features ImageDaikin RXQ-ARYFK VRV VRT ImageDaikin RXQ-ARYFK VRV Features ImageDaikin RXQ-ARYFK VRV Features ImageDaikin RXQ-ARYFK VRV Madoka ImageDaikin RXQ-ARYFK VRV Technical Specifications Image